SMARTech   Library Home
 

Georgia Tech's Institutional Repository >
Georgia Tech Theses and Dissertations >
Georgia Tech Theses and Dissertations >

Please use this identifier to cite or link to this item: http://hdl.handle.net/1853/29761

Title: Time-sensitive communication of digital images, with applications in telepathology
Authors: Khire, Sourabh Mohan
Electrical and Computer Engineering
Advisor: Committee Chair: Jayant, Nikil; Committee Member: Anderson, David; Committee Member: Lee, Chin-Hui
Subjects : Image transmission
Image compression
Telepathology
Whole slide images
Issue Date: 8-Jul-2009
Publisher: Georgia Institute of Technology
Abstract: Telepathology is defined as the practice of pathology at a distance using video imaging and telecommunications. In this thesis we address the two main technology challenges in implementing telepathology, viz. compression and transmission of digital pathology images. One of the barriers to telepathology is the availability and the affordability of high bandwidth communication resources. High bandwidth links are required because of the large size of the uncompressed digital pathology images. For efficient utilization of available bandwidth, these images need to be compressed. However aggressive image compression may introduce objectionable artifacts and result in an inaccurate diagnosis. This discussion helps us to identify two main design challenges in implementing telepathology, 1. Compression: There is a need to develop or select an appropriate image compression algorithm and an image quality criterion to ensure maximum possible image compression, while ensuring that diagnostic accuracy is not compromised. 2. Transmission: There is a need to develop or select a smart image transmission scheme which can facilitate the transmission of the compressed image to the remote pathologist without violating the specified bandwidth and delay constraints. We addressed the image compression problem by conducting subjective tests to determine the maximum compression that can be tolerated before the pathology images lose their diagnostic value. We concluded that the diagnostically lossless compression ratio is at least around 5 to 10 times higher than the mathematically lossless compression ratio, which is only about 2:1. We also set up subjective tests to compare the performance of the JPEG and the JPEG 2000 compression algorithms which are commonly used for compression of medical images. We concluded that JPEG 2000 outperforms JPEG at lower bitrates (bits/pixel), but both the algorithms perform equally well at higher bitrates. We also addressed the issue of image transmission for telepathology by proposing a two-stage transmission scheme, where coarse image information compressed at diagnostically lossless level is sent to the clients at the first stage, and the Region of Interest is transmitted at mathematically lossless compression levels at the second stage, thereby reducing the total image transmission delay.
Type: Thesis
URI: http://hdl.handle.net/1853/29761
Appears in Collections:School of Electrical and Computer Engineering Theses and Dissertations
Georgia Tech Theses and Dissertations

Files in This Item:

File Description SizeFormat
khire_sourabh_m_200908_mast.pdf5.59 MBAdobe PDFView/Open

Items in SMARTech are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2007 MIT and Hewlett-Packard - Feedback