Show simple item record

dc.contributor.advisorAidun, Cyrus K.
dc.contributor.authorFouts, John Lyleen_US
dc.date.accessioned2006-06-09T17:50:12Z
dc.date.available2006-06-09T17:50:12Z
dc.date.issued2005-12-21en_US
dc.identifier.urihttp://hdl.handle.net/1853/10423
dc.description.abstractThe aim of this study was to characterize the interaction between a pulsed ultrasonic wave and a paper forming screen for potential development of a smart paper forming sensor to measure velocity profile of the forming jet as it impinges on the wire. To achieve this goal, a Signal-Processing DOP 2000 pulsed ultrasonic Doppler velocimeter was used to generate a pulsed ultrasonic signal. The signal was transmitted and received using four different ultrasonic transducers: a 2 MHz 10 mm, 4 MHz 5 mm, 4MHz 8 mm focused, and 8 MHz 5 mm. The ultrasonic signals were then analyzed in order to determine the ultrasonic beam echo amplitude and shape. These tests were performed with and without various paper forming screens placed between the ultrasonic transducer and an ultrasonic signal target. Two different paper forming screens were utilized to study the interaction of the ultrasonic beam with the forming screens. The tests showed that the ultrasonic signal passing through the forming screens is greatly attenuated causing a sharp decrease in echo amplitude. To overcome the attenuation of the signal, a much higher amplification of the signal was used causing an increase in the saturation region around the forming screen. This increased the minimum distance that a target had to be away from the forming screen. The closest distance from the plastic sphere to the screen over the widest range of transducer-screen-distances that produced detectable echoes was achieved with the 4 MHz 5 mm transducer. The tests showed for both screens that there is more variation in beam width when the screen is moved laterally than when it is not moved at all. They also show that even though the pores in the forming screen are very small, they seem to have a great effect on the beam width measurements of the ultrasonic transducer.en_US
dc.format.extent1010297 bytes
dc.format.mimetypeapplication/pdf
dc.language.isoen_US
dc.publisherGeorgia Institute of Technologyen_US
dc.subjectPUDVen_US
dc.subjectUltrasound
dc.subjectAcoustic
dc.subjectFluid dynamics
dc.subjectPaper forming screen
dc.titleForming Screen Effect on Ultrasonic Beam Fielden_US
dc.typeText
dc.description.degreeM.S.en_US
dc.contributor.departmentMechanical Engineeringen_US
dc.contributor.committeeMemberDavid Orloff
dc.contributor.committeeMemberTimothy Patterson
dc.type.genreThesis


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record