    A Three-Stage Stirling Pulse Tube Cryocooler Approaching 4 K

    Thumbnail
    View/Open
    004.pdf (779.5Kb)
    Date
    2008-05
    Author
    Cao, Q.
    Qiu, Limin
    Gan, Zhihua
    Yu, Y. B.
    Zhi, X. Q.
    Metadata
    Show full item record
    Abstract
    It is a great challenge for a Stirling Pulse tube cryocooler (PTC) to reach liquid-helium temperature, where there are promising applications such as superconducting digital electronics, midinfrared instrument, heterodyne detectors. Lockheed Martin first achieved a temperature below 4 K with a four-stage configuration with He-3 as working fluid. A single-stage Stirling PTC precooled by a self-made two-stage GM-type PTC has been constructed and tested to explore the loss mechanism of 4 K PTC working at high frequency at Zhejiang University. Temperature as low as 4.2 K has been successfully obtained with He-4 as working fluid by the end of 2008. In this paper, we report a newly-designed three-stage PTC, which aims to reach 4 K. The 4 K cooler is a thermalcoupled type, whose mass flows are easier t ocontrol and whose energy flows are more readily monitored. It will be working with He-4 instead of He-3. The first and second stages have been finished. A bottom temperature of 35 K and 9 W at 77 K with 300 We input has been achieved in the first stage. The bottom temperature of second stage is as low as 20.6 K, and the cooling power is measured as 1.0 W at 28.6 K. The test results are in good agreement with the model for both stages. The first and second stage is designed to couple with the a stage, which is expected to reach below 5.0 K at 30 Hz.
    URI
    http://hdl.handle.net/1853/38743
    Collections
    • International Cryocooler Conference (16th - 2008 - Atlanta, GA) [89]

    Browse

    All of SMARTechCommunities & CollectionsDatesAuthorsTitlesSubjectsTypesThis CollectionDatesAuthorsTitlesSubjectsTypes

    My SMARTech

    Login

    Statistics

    View Usage StatisticsView Google Analytics Statistics
    facebook instagram twitter youtube
    • My Account
    • Contact us
    • Directory
    • Campus Map
    • Support/Give
    • Library Accessibility
      • About SMARTech
      • SMARTech Terms of Use
    Georgia Tech Library266 4th Street NW, Atlanta, GA 30332
    404.894.4500
    • Emergency Information
    • Legal and Privacy Information
    • Human Trafficking Notice
    • Accessibility
    • Accountability
    • Accreditation
    • Employment
    © 2020 Georgia Institute of Technology