Show simple item record

dc.contributor.authorde Julien de Zelicourt, Diane Aliciaen_US
dc.date.accessioned2005-03-01T19:38:06Z
dc.date.available2005-03-01T19:38:06Z
dc.date.issued2004-12-09en_US
dc.identifier.urihttp://hdl.handle.net/1853/4882
dc.description.abstractBACKGROUND: Understanding the hemodynamics of the total cavopulmonary connection (TCPC) may lead to further optimization of the connection design and surgical planning, which in turn may lead to improved surgical outcome. While most experimental and numerical investigations have mainly focused on somewhat simplified geometries, the investigation of the flow field of true TCPC configurations is necessary for a true understanding. METHODS: This study details a manufacturing methodology yielding more accurate in vitro models that would provide a better understanding of the TCPC hemodynamics and adequate data for the validation of anatomical CFD simulations. This approach is illustrated on two different TCPC templates: an intra-atrial TCPC with a single superior vena cava (SVC) and a bilateral SVC with an extra-cardiac conduit. Power loss, flow visualization, digital particle image velocimetry (DPIV) flow measurements as well as computational fluid dynamics simulations are performed to characterize the anatomic flow structure. Additional parametric glass models of the TCPC were manufactured to help understand the fluid dynamics of the anatomical models and support the computational model validation effort. RESULTS/CONCLUSIONS: Both anatomic configurations revealed very different fluid dynamics underlining once again the need for at least one comprehensive experimental campaign per TCPC template for a good understanding of the flow phenomena. The absence of caval offset in the anatomical intra-atrial model resulted in important flow turbulence, which was enhanced by the large connection area and yielded high pressure drops and power losses. On the other hand, the bilateral SVC, which featured a smooth extra-cardiac conduit and wider vessels, led to power losses that were one order of magnitude lower than those of the anatomic intra-atrial model and a smooth flow field with lower levels of instability. The simplified glass models demonstrated that the diameter of the connecting vessels and of the pulmonary arteries in particular, was a parameter of prime importance. Finally, this study also reports on a combined experimental and numerical validation methodology, suggesting a cautious approach for the straightforward use of available CFD tools and pointing out the need for developing high resolution CFD techniques specifically tailored to tackle the complexities of cardiovascular flows.en_US
dc.format.extent83739 bytes
dc.format.extent43198 bytes
dc.format.extent1396937 bytes
dc.format.extent146950 bytes
dc.format.extent112991 bytes
dc.format.extent188297 bytes
dc.format.extent151904 bytes
dc.format.extent161682 bytes
dc.format.extent12287922 bytes
dc.format.mimetypevideo/quicktime
dc.format.mimetypevideo/quicktime
dc.format.mimetypevideo/quicktime
dc.format.mimetypevideo/quicktime
dc.format.mimetypevideo/quicktime
dc.format.mimetypevideo/quicktime
dc.format.mimetypevideo/quicktime
dc.format.mimetypevideo/quicktime
dc.format.mimetypeapplication/pdf
dc.language.isoen_US
dc.publisherGeorgia Institute of Technologyen_US
dc.subjectIntra-atrialen_US
dc.subjectExtra-cardiac
dc.subjectBilateral SVC
dc.subjectIn vitro experiments
dc.subjectTCPC
dc.subjectFontan
dc.subjectDPIV
dc.subjectPower losses
dc.titleA Mechanical Fluid Assessment of Anatomical Models of the Total Cavopulmonary Connection (TCPC)en_US
dc.typeThesisen_US
dc.description.degreeM.S.en_US
dc.contributor.departmentBiomedical Engineeringen_US
dc.description.advisorCommittee Chair: Ajit Yoganathan; Committee Member: Don Giddens; Committee Member: Shiva Sharmaen_US


Files in this item

Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record