    Measurement of Finned-Tube Heat Exchanger Performance

    Thumbnail
    View/Open
    Taylor_Creed_200412_MAST.pdf (2.451Mb)
    Date
    2004-12-01
    Author
    Taylor, Creed
    Metadata
    Show full item record
    Abstract
    Finned-tube heat exchangers are predominantly used in space conditioning systems, as well as other applications requiring heat exchange between two fluids. One important widespread use is in residential air conditioning systems. These residential cooling systems influence the peak demand on the U.S. national electrical system, which occurs on the hot summer afternoons, and thereby sets the requirement for the expensive infrastructure requirement of the nations power plant and electrical distribution system. In addition to this peak demand, these residential air conditioners are major energy users that dominate residential electrical costs and environmental impact. The design of finned-tube heat exchangers requires the selection of over a dozen design parameters by the designer. The refrigerant side flow and heat transfer characteristics inside the tubes have been thoroughly studied. However, the air side flow around the tube bundle and through the fin gaps is much more complex and depends on over a dozen design parameters. Therefore, experimental measurement of the air side performance is needed. First this study built an experimental system and developed methodology for measuring the air side heat transfer and pressure drop characteristics of fin tube heat exchangers. This capability was then used to continue the goal of expanding and clarifying the present knowledge and understanding of air side performance to enable the air conditioner system designer in verifying an optimum fin tube condenser design. In this study eight fin tube heat exchangers were tested over an air flow face velocity range of 5 ?? ft/s (675-1600cfm). The raw data were reduced to the desired heat transfer and friction data, j and f factors. This reduced heat transfer and friction data was plotted versus Reynolds number and compared. The effect of fin spacing, the number of rows and fin enhancement were all investigated. The heat transfer and friction data were also plotted and compared with various correlations available from open literature. The overall accuracy of each correlation to predict experimental data was calculated. Correlations by C.C. Wang (1998b, 1999) showed the best agreement with the data. Wangs correlations (1998b, 1999) were modified to fit the current studys data.
    URI
    http://hdl.handle.net/1853/4890
    Collections
    • Georgia Tech Theses and Dissertations [23403]
    • School of Mechanical Engineering Theses and Dissertations [4008]

    Browse

    All of SMARTechCommunities & CollectionsDatesAuthorsTitlesSubjectsTypesThis CollectionDatesAuthorsTitlesSubjectsTypes

    My SMARTech

    Login

    Statistics

    View Usage StatisticsView Google Analytics Statistics
    facebook instagram twitter youtube
    • My Account
    • Contact us
    • Directory
    • Campus Map
    • Support/Give
    • Library Accessibility
      • About SMARTech
      • SMARTech Terms of Use
    Georgia Tech Library266 4th Street NW, Atlanta, GA 30332
    404.894.4500
    • Emergency Information
    • Legal and Privacy Information
    • Human Trafficking Notice
    • Accessibility
    • Accountability
    • Accreditation
    • Employment
    © 2020 Georgia Institute of Technology