    Influence of the Implant Location on the Hinge and Leakage Flow Fields Through Bileaflet Mechanical Heart Valves

    Thumbnail
    View/Open
    simon_helene_a_200405_mast_hinge_cm_flatlevel.mov (510.0Kb)
    simon_helene_a_200405_mast_hinge_sjm_500micronslevel.mov (603.1Kb)
    simon_helene_a_200405_mast_hinge_sjm_1mmlevel.mov (601.4Kb)
    simon_helene_a_200405_mast_hinge_sjm_3mmlevel.mov (588.4Kb)
    simon_helene_a_200405_mast_hinge_sjm_195micronslevel.mov (447.0Kb)
    simon_helene_a_200405_mast_hinge_sjm_390micronslevel.mov (564.7Kb)
    simon_helene_a_200405_mast_hinge_cm_195micronslevel.mov (522.9Kb)
    simon_helene_a_200405_mast_hinge_cm_1mmlevel.mov (521.6Kb)
    simon_helene_a_200405_mast_hinge_cm_390micronslevel.mov (409.8Kb)
    simon_helene_a_200405_mast_hinge_sjm_flatlevel.mov (597.2Kb)
    simon_helene_a_200405_mast_leakagejets_cm_space.mpg (904.1Kb)
    simon_helene_a_200405_mast_leakagejets_cm_time.mov (985.9Kb)
    simon_helene_a_200405_mast_leakagejets_sjm_space.mpg (954.0Kb)
    simon_helene_a_200405_mast_leakagejets_sjm_time.mov (761.8Kb)
    helene_simon_a_200405_mast.pdf (8.670Mb)
    Date
    2004-04-08
    Author
    Simon, Helene A.
    Metadata
    Show full item record
    Abstract
    Native heart valves that have limited functionality due to cardiovascular disease or congenital birth defects are commonly replaced by prosthetic heart valves. Bileaflet mechanical heart valves (BMHV) are the most commonly implanted valve design due to their long-term durability. However, their unnatural hemodynamics promote thrombosis and thromboembolic events. Clinical reports and in vitro experiments suggest that the thrombogenic complications in bileaflet valves are related to the stress imposed on blood by the valves during the closing phase. Additionally, animal and clinical studies have shown that BMHV in the aortic position demonstrate reduced failure rates compared to identical valves in the mitral position. The present study aimed to investigate the leakage, hinge, and near hinge flow fields of two BMHV under simulated physiologic aortic flow conditions and to compare these results with previous findings in the mitral position to better understand how the implant location influences the valve performance and the subsequent risk of blood damage. Two and three-component Laser Doppler Velocimetry techniques were used to quantify the velocity and turbulent shear stress fields in both the hinge and the upstream leakage flow regions. The study focused on the 23 mm St. Jude Medical Regent (SJM) and the 23 mm CarboMedics (CM) valves. Although they were tested under similar physiologic conditions, shape and location of the leakage jets were dependent on valve design. Nevertheless, turbulent shear stress levels recorded within all jets were well above the threshold shear stress for the onset of blood cell damage. Within the hinge region, the flow fields were complex and unsteady. The angulated hinge recess of the CM valve appeared to promote blood damage while the streamlined geometry of the SJM valve contributed to better washout of the hinge region. Animations of the velocity flow fields are given in QuickTime or MPEG format. Comparison of the present findings with previously published results for the mitral position suggests that the superior clinical results of the mechanical valves in the aortic position may be due to less severe leakage flow upon valve closure as well as to enhanced hinge washout during the forward flow phase.
    URI
    http://hdl.handle.net/1853/5159
    Collections
    • Georgia Tech Theses and Dissertations [23877]
    • School of Chemical and Biomolecular Engineering Theses and Dissertations [1516]

    Browse

    All of SMARTechCommunities & CollectionsDatesAuthorsTitlesSubjectsTypesThis CollectionDatesAuthorsTitlesSubjectsTypes

    My SMARTech

    Login

    Statistics

    View Usage StatisticsView Google Analytics Statistics
    facebook instagram twitter youtube
    • My Account
    • Contact us
    • Directory
    • Campus Map
    • Support/Give
    • Library Accessibility
      • About SMARTech
      • SMARTech Terms of Use
    Georgia Tech Library266 4th Street NW, Atlanta, GA 30332
    404.894.4500
    • Emergency Information
    • Legal and Privacy Information
    • Human Trafficking Notice
    • Accessibility
    • Accountability
    • Accreditation
    • Employment
    © 2020 Georgia Institute of Technology