• Login
    View Item 
    •   SMARTech Home
    • Georgia Tech Theses and Dissertations
    • Georgia Tech Theses and Dissertations
    • View Item
    •   SMARTech Home
    • Georgia Tech Theses and Dissertations
    • Georgia Tech Theses and Dissertations
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A comprehensive analysis of potential factors for transcatheter aortic valve thrombosis risk

    Thumbnail
    View/Open
    MADUKAUWADAVID-DISSERTATION-2019.pdf (124.3Mb)
    Date
    2019-04-24
    Author
    Madukauwa David, Immanuel David
    Metadata
    Show full item record
    Abstract
    Transcatheter aortic valve replacement (TAVR) is indicated for aortic stenosis (AS) patients who are deemed intermediate or greater surgical risk. Recent evidence of leaflet thrombosis and reduced leaflet mobility in TAVR devices has led to concerns of stroke and long-term valve durability. Risk factors for thrombosis in TAVR patients remain poorly defined. While materials and blood chemistry are likely to be contributing factors to thrombosis risk, early clinical evidence and experimental data demonstrate that fluid dynamics in the specific setting of the transcatheter aortic valve (TAV) are a major factor in the development of leaflet thrombosis. This environment can be altered by anatomical, procedural, and device related parameters. Additionally, it has been demonstrated that the thrombus originates in the “neo-sinus,” which is the pocket formed between the TAV leaflets and the native aortic valve leaflets. This study, organized in three parts, aimed to elucidate the contribution of anatomical, deployment, and fluid dynamic factors to a thrombogenic environment in the neo-sinus region of transcatheter aortic valves via analyses of clinical imaging data and a battery of in vitro experiments on select commercial TAVs and their replicas. The first segment of this study demonstrated that certain aortic root anatomical dimensions and TAV deployment characteristics influence neo-sinus thrombus incidence and severity in TAVR patients as determined by an analysis of CT scans. In the second segment of this study, it was demonstrated by laser-induced fluorescence that a higher implantation of the CoreValve improves neo-sinus fluid washout, and slight under-expansion of both the CoreValve and the SAPIEN 3 improve fluid washout of the region. Furthermore, these trends were replicated in a subset of experiments using an aortographic benchtop washout technique at normal and low cardiac outputs. An analysis of retrospective routinely-acquired clinical aortographic data confirmed the trend of TAV expansion yielding improved neo-sinus washout. This established aortography as a potential means of peri-procedurally evaluating TAVR patient flow-related thrombosis risk. The last segment of this study demonstrated that the TAV cusp most proximal to the native LCC has less flow stasis as a result of coronary flow in its vicinity compared to the TAV cusp proximal to the native NCC. This trend was seen in a supra-annular TAV replica and but not the intra-annular replica. This thesis work facilitated an understanding of how certain anatomical and TAV deployment characteristics relate to neo-sinus thrombosis risk and severity particularly with respect to the Virchow’s triad factor, flow stasis. These findings may be instrumental in improving patient outcomes as device deployment criteria and device design are fine-tuned in the near future.
    URI
    http://hdl.handle.net/1853/63491
    Collections
    • Georgia Tech Theses and Dissertations [23877]
    • School of Mechanical Engineering Theses and Dissertations [4086]

    Browse

    All of SMARTechCommunities & CollectionsDatesAuthorsTitlesSubjectsTypesThis CollectionDatesAuthorsTitlesSubjectsTypes

    My SMARTech

    Login

    Statistics

    View Usage StatisticsView Google Analytics Statistics
    facebook instagram twitter youtube
    • My Account
    • Contact us
    • Directory
    • Campus Map
    • Support/Give
    • Library Accessibility
      • About SMARTech
      • SMARTech Terms of Use
    Georgia Tech Library266 4th Street NW, Atlanta, GA 30332
    404.894.4500
    • Emergency Information
    • Legal and Privacy Information
    • Human Trafficking Notice
    • Accessibility
    • Accountability
    • Accreditation
    • Employment
    © 2020 Georgia Institute of Technology