Show simple item record

dc.contributor.authorNair, Priya
dc.date.accessioned2021-06-30T17:36:56Z
dc.date.available2021-06-30T17:36:56Z
dc.date.created2020-05
dc.date.submittedMay 2020
dc.identifier.urihttp://hdl.handle.net/1853/64831
dc.description.abstractTranscatheter aortic valve replacement (TAVR) is a minimally invasive technique introduced to treat patients with aortic stenosis who are at high surgical risk. Despite its advantages over the traditional open-heart surgery technique, several complications including thrombosis are being increasingly reported. Much of the research so far has focused on the impact that fluid dynamics has on thrombosis. This study explores the contribution of the different foreign materials in the TAV to the initiation of thrombus formation. A steady flow loop with minimized volume was developed such that multiple experiments could be conducted with blood from a single human donor. Three conditions - control, stent-with-skirt, and whole valve - were tested using the flow loop at two different anticoagulant: reversing agent ratios (8:1 and 6:1). Serum collected from blood samples drawn at the start and end of the experiment were used to measure concentrations of D-dimer and thrombin anti-thrombin (TAT), biomarkers of thrombosis. Higher D-dimer and TAT concentrations in the stent-with-skirt compared to the valve in the 8:1 condition suggest that, over time, exposure to the stent with the skirt can shift the blood to a more prothrombotic state. Lack of significant differences between groups in the 6:1 condition indicates that when blood is already in a significantly high prothrombotic state, different materials of the TAV do not have significantly different effects on thrombus formation. The results of this study help to better understand the process of initiation of thrombus formation in TAV from a foreign materials perspective.
dc.format.mimetypeapplication/pdf
dc.language.isoen_US
dc.publisherGeorgia Institute of Technology
dc.subjectThrombosis
dc.subjectTranscatheter aortic valve
dc.subjectForeign material
dc.subjectD-dimer
dc.subjectThrombin-antithrombin
dc.titleEffect of transcatheter aortic valve materials on thrombogenesis
dc.typeUndergraduate Research Option Thesis
dc.description.degreeUndergraduate
dc.contributor.departmentBiomedical Engineering (Joint GT/Emory Department)
thesis.degree.levelUndergraduate
dc.contributor.committeeMemberYoganathan, Ajit
dc.contributor.committeeMemberDasi, Lakshmi
dc.date.updated2021-06-30T17:36:56Z


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record